Can't find what you're looking for? Try our old website for IBECO.
Go to old websiteKrausz Eu·Mounting boxes
The market's simplest and most effective installation box – up to 60% fewer bolts and quick installation, removal and adjustment.
The Hymax installation box is used to join, replace or fit pipe fittings into pressurised pipelines, and is available for sizes DN80 to DN1000 in pressure class PN10 and PN16 respectively. The box is built from steel with a double-acting gasket that provides very good mechanical and hydraulic sealing properties, and withstands a working pressure of 10 or 16 bar depending on the version. Installation, removal and adjustment are carried out in simple steps with up to 60 percent fewer bolts than a standard box. The adjustability is ± 40 mm for DN80–150, ± 65 mm for DN200–600 and ± 40 mm for DN700–1000. The bolts are tightened to the specified torque, which depending on size is between 45 and 400 Nm.
26 variants
| Item no. | Description | DN | Pressureclass | L minmm | L maxmm | Workingpressurebar | MaxNm | Amm | Bmm | Bolt quantityx dim | Quote |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 804-825-0048-16 | Hymax installation box DN1200 PN16 | 1200 | PN16 | — | — | — | — | — | — | — | |
| 807-825-0048-10 | Hymax installation box DN1200 PN10 | 1200 | PN10 | — | — | — | — | — | — | — | |
| 3481809 | Hymax installation box DN80 PN10/16 | 80 | PN10/16 | 210 | 290 | 16 | 45 | 430 | 70 | 2 x M16 | |
| 3481810 | Hymax installation box DN100 PN10/16 | 100 | PN10/16 | 210 | 290 | 16 | 45 | 430 | 70 | 2 x M16 | |
| 3481812 | Hymax installation box DN150 PN10/16 | 150 | PN10/16 | 220 | 300 | 16 | 60 | 450 | 70 | 4 x M20 | |
| 3481813 | Hymax installation box DN200 PN10 | 200 | PN10 | 270 | 400 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481814 | Hymax installation box DN200 PN16 | 200 | PN16 | 270 | 400 | 16 | 80 | 570 | 80 | 4 x M20 | |
| 3481815 | Hymax installation box DN250 PN10 | 250 | PN10 | 270 | 400 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481816 | Hymax installation box DN250 PN16 | 250 | PN16 | 280 | 410 | 16 | 80 | 600 | 80 | 4 x M24 | |
| 3481817 | Hymax installation box DN300 PN10 | 300 | PN10 | 280 | 410 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481818 | Hymax installation box DN300 PN16 | 300 | PN16 | 300 | 430 | 16 | 80 | 600 | 80 | 4 x M24 | |
| 3481819 | Hymax installation box DN350 PN10 | 350 | PN10 | 290 | 420 | 10 | 80 | 600 | 85 | 4 x M20 | |
| 3481820 | Hymax installation box DN350 PN16 | 350 | PN16 | 300 | 430 | 16 | 80 | 600 | 85 | 4 x M24 | |
| 3481821 | Hymax installation box DN400 PN10 | 400 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481822 | Hymax installation box DN400 PN16 | 400 | PN16 | 370 | 500 | 16 | 100 | 700 | 100 | 4 x M27 | |
| 3481823 | Hymax installation box DN450 PN10 | 450 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481824 | Hymax installation box DN450 PN16 | 450 | PN16 | 370 | 500 | 16 | 100 | 700 | 100 | 4 x M27 | |
| 3481825 | Hymax installation box DN500 PN10 | 500 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481826 | Hymax installation box DN500 PN16 | 500 | PN16 | 380 | 510 | 16 | 100 | 730 | 110 | 4 x M30 | |
| 3481827 | Hymax installation box DN600 PN10 | 600 | PN10 | 370 | 500 | 10 | 130 | 700 | 100 | 4 x M27 | |
| 3481828 | Hymax installation box DN600 PN16 | 600 | PN16 | 410 | 540 | 16 | 130 | 780 | 120 | 4 x M33 | |
| 3481830 | Hymax installation box DN700 PN16 | 700 | PN16 | 350 | 430 | 16 | 300 | 700 | 130 | 8 x M33 | |
| 3481832 | Hymax installation box DN800 PN16 | 800 | PN16 | 360 | 440 | 16 | 300 | 720 | 140 | 8 x M36 | |
| 3481834 | Hymax installation box DN900 PN16 | 900 | PN16 | 380 | 460 | 16 | 400 | 760 | 150 | 8 x M36 | |
| 3481835 | Hymax installation box DN1000 PN10 | 1000 | PN10 | 350 | 430 | 10 | 400 | 720 | 140 | 8 x M33 |
Visar 25 av 26
| Component | Material | Standard |
|---|---|---|
| Body | Steel S235JR | EN 10025-2 (DIN 17100) |
| Gasket | EPDM | 681-1 |
| Bolt | Stainless steel 1.4301, surface treated against cutting | – |

| Surface treatment |
| Epoxy coating |
| DIN 30677-2 |
26 variants
| Item no. | Description | DN | Pressureclass | L minmm | L maxmm | Workingpressurebar | MaxNm | Amm | Bmm | Bolt quantityx dim | Quote |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 804-825-0048-16 | Hymax installation box DN1200 PN16 | 1200 | PN16 | — | — | — | — | — | — | — | |
| 807-825-0048-10 | Hymax installation box DN1200 PN10 | 1200 | PN10 | — | — | — | — | — | — | — | |
| 3481809 | Hymax installation box DN80 PN10/16 | 80 | PN10/16 | 210 | 290 | 16 | 45 | 430 | 70 | 2 x M16 | |
| 3481810 | Hymax installation box DN100 PN10/16 | 100 | PN10/16 | 210 | 290 | 16 | 45 | 430 | 70 | 2 x M16 | |
| 3481812 | Hymax installation box DN150 PN10/16 | 150 | PN10/16 | 220 | 300 | 16 | 60 | 450 | 70 | 4 x M20 | |
| 3481813 | Hymax installation box DN200 PN10 | 200 | PN10 | 270 | 400 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481814 | Hymax installation box DN200 PN16 | 200 | PN16 | 270 | 400 | 16 | 80 | 570 | 80 | 4 x M20 | |
| 3481815 | Hymax installation box DN250 PN10 | 250 | PN10 | 270 | 400 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481816 | Hymax installation box DN250 PN16 | 250 | PN16 | 280 | 410 | 16 | 80 | 600 | 80 | 4 x M24 | |
| 3481817 | Hymax installation box DN300 PN10 | 300 | PN10 | 280 | 410 | 10 | 80 | 570 | 80 | 4 x M20 | |
| 3481818 | Hymax installation box DN300 PN16 | 300 | PN16 | 300 | 430 | 16 | 80 | 600 | 80 | 4 x M24 | |
| 3481819 | Hymax installation box DN350 PN10 | 350 | PN10 | 290 | 420 | 10 | 80 | 600 | 85 | 4 x M20 | |
| 3481820 | Hymax installation box DN350 PN16 | 350 | PN16 | 300 | 430 | 16 | 80 | 600 | 85 | 4 x M24 | |
| 3481821 | Hymax installation box DN400 PN10 | 400 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481822 | Hymax installation box DN400 PN16 | 400 | PN16 | 370 | 500 | 16 | 100 | 700 | 100 | 4 x M27 | |
| 3481823 | Hymax installation box DN450 PN10 | 450 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481824 | Hymax installation box DN450 PN16 | 450 | PN16 | 370 | 500 | 16 | 100 | 700 | 100 | 4 x M27 | |
| 3481825 | Hymax installation box DN500 PN10 | 500 | PN10 | 360 | 490 | 10 | 100 | 700 | 100 | 4 x M24 | |
| 3481826 | Hymax installation box DN500 PN16 | 500 | PN16 | 380 | 510 | 16 | 100 | 730 | 110 | 4 x M30 | |
| 3481827 | Hymax installation box DN600 PN10 | 600 | PN10 | 370 | 500 | 10 | 130 | 700 | 100 | 4 x M27 | |
| 3481828 | Hymax installation box DN600 PN16 | 600 | PN16 | 410 | 540 | 16 | 130 | 780 | 120 | 4 x M33 | |
| 3481830 | Hymax installation box DN700 PN16 | 700 | PN16 | 350 | 430 | 16 | 300 | 700 | 130 | 8 x M33 | |
| 3481832 | Hymax installation box DN800 PN16 | 800 | PN16 | 360 | 440 | 16 | 300 | 720 | 140 | 8 x M36 | |
| 3481834 | Hymax installation box DN900 PN16 | 900 | PN16 | 380 | 460 | 16 | 400 | 760 | 150 | 8 x M36 | |
| 3481835 | Hymax installation box DN1000 PN10 | 1000 | PN10 | 350 | 430 | 10 | 400 | 720 | 140 | 8 x M33 |
Visar 25 av 26