Can't find what you're looking for? Try our old website for IBECO.
Go to old websiteBermad·Flow meters
Electromagnetic flow meter M10 with grooved coupling (Victaulic OGS), DN50–DN150. Light and compact, with Bluetooth and Modbus.
The M10 is an electromagnetic flow meter with a grooved connection for DN50–DN150. It is light and compact and measures low flows accurately as well, even when the water contains particles. The meter has no moving parts, requires neither filter nor maintenance, and measures in both directions. The internal components are protected by a two-component resin. Applications: irrigation, district metering of drinking water, water distribution, small installations without straight pipe runs, and very low or very high flows. Technical data: - Pressure class: PN16 - Connection: Victaulic OGS (grooved coupling), flanges up to PN16 or ANSI 150 - Conductivity: above 20 µS/cm - Accuracy: 0.2 % ± 2 mm/s, repeatability approximately 0.1 % - Flow velocity: 0.015–10 m/s - Ingress protection: IP68 - Power supply: 3.6 V lithium battery or 12 VDC (10.8–13.2 V, max 100 mA), consumption 0.25–1 W on mains operation - Outputs: 2 passive SSR outputs (1 programmable), galvanically isolated, max ±35 VDC, 100 mA - Communication: RS485 Modbus RTU and Bluetooth - Display: LCD, 8+6 digits - Data logger: 100,000 rows, logging interval 1–120 minutes (15 minutes from the factory) - Counters: 5 (2 positive, 2 negative, 1 net) Temperatures: - Medium: 0 °C / +80 °C - Ambient: -20 °C / +60 °C - Storage: -40 °C / +70 °C Standards: - 2014/53/EU - 2014/30/EU – EN 61326-1:2013 (EMC) - 2014/65/EU - EN IEC 60529 - OIML R49-1:2013 - European directive 2014/32/EU (MID), class 2 on request
4 variants
| Item no. | DN | Demm | L1mm | L2mm | L3mm | L4mm | Q1m³/h | Q2m³/h | Q3m³/h | Q4m³/h | Quote |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FMIR050 | 50 | 60,3 | 230 | 100 | 150 | 200 | 0,1 | 0,16 | 40 | 50 | |
| FMIR080 | 80 | 88,6 | 230 | 100 | 150 | 225 | 0,25 | 0,4 | 100 | 125 | |
| FMIR100 | 100 | 114,3 | 230 | 100 | 150 | 250 | 0,4 | 0,64 | 160 | 200 | |
| FMIR150 | 150 | 168,3 | 300 | 100 | 210 | 300 | 1 | 1,6 | 400 | 500 |
| Component | Material |
|---|---|
| Measuring tube | Glass-fibre reinforced plastic |
| Electrodes | Stainless steel AISI 316L |

4 variants
| Item no. | DN | Demm | L1mm | L2mm | L3mm | L4mm | Q1m³/h | Q2m³/h | Q3m³/h | Q4m³/h | Quote |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FMIR050 | 50 | 60,3 | 230 | 100 | 150 | 200 | 0,1 | 0,16 | 40 | 50 | |
| FMIR080 | 80 | 88,6 | 230 | 100 | 150 | 225 | 0,25 | 0,4 | 100 | 125 | |
| FMIR100 | 100 | 114,3 | 230 | 100 | 150 | 250 | 0,4 | 0,64 | 160 | 200 | |
| FMIR150 | 150 | 168,3 | 300 | 100 | 210 | 300 | 1 | 1,6 | 400 | 500 |